- Industrial Hygiene
- Environmental
- Analytical Laboratory
- Disc Filter Membrane
- Glass Fiber
- Silver Filter Membrane
- Ceramic Filter Membrane
- Aluminum Oxide Filter Membrane
- Mixed Cellulose Ester (MCE) Filter Membrane
- Nylon Filter Membrane
- Polytetrafluorothylene (PTFE) Filter Membrane
- Cellulose Acetate (CA) Filter Membrane
- Hydrophilic Polycarbonate (PCTE) Filter Membrane
- Hydrophobic Polycarbonate (PCTE) Filter Membranes
- PVDF Filter Membrane
- Polypropylene (PP) Filter Membrane
- Polyethersulfone (PES) Filter Membrane
- Polyacrylonitrile (PAN) Filter Membrane
- Hydrophilic, Polyester Track Etch (PETE) Filter Membrane
- Hydrophobic Polyester (PETE) Filter Membrane
- Polyether Ether Ketone (PEEK) Filter Membrane
- Regenerated Cellulose (RC) Filter Membrane
- Quantitative Filter Paper
- Qualitative Filter Paper
- Syringe Filter
- In-line Filter
- Botanical Filter Paper
- Microbiology
- Others
- Disc Filter Membrane
Inter Products Marketing Sdn Bhd
Klang, Selangor, Malaysia.
+6016-305 9138
dBAir GA241SE Safety and Environment Sound Level Meter
Previous | 1 / 9 | Next |
Castle / GA241SE
dBAir GA241SE Safety and Environment Sound Level Meter
dBAir Safety and Environment Sound Level Meter GA241SE c/w Windshield KG205 and dBAir USB
For not only compliant measurements to IEC 61671-1:2002 for accurate Noise at Work Assessments, but also a whole host of Environmental Assessments, the dBAir Safety & Environment is the latest multi-application Sound Meter from Castle. This is the only instrument you’ll ever need, making it the extremely popular choice with Safety Professionals and Environmental Health Officers alike.
Exposure Assessments
Factory Noise Mapping
SNR and HML Hearing Protection Assessment
Litigation Defence
Hand-held environmental measurements
Boundary noise checking
BS4142 checks
Construction noise
Compliance testing
Technical Specification
Applicable Standards | IEC 61672-1:2013 IEC 61260-1:2014 (Where Octave Bands Fitted) IEC 61252:1993 amendment 1:2000 (Where Exposure Fitted) | |||||||||||
Microphone | Type 2 Pre-Polarised ½” (25mV/Pa) Condenser Microphone –32 dB ± 3 dB re 1V/Pa | |||||||||||
Measurement Ranges | Linear Operating Range: 95dB | |||||||||||
Noise Floor | Typical ’A’ WeightingFrequency WeightingsMeasurement 1: A, C or Z Measurement 2: A, C or Z | |||||||||||
Frequency Range | 1 Hz - 20 kHz (electrical characteristics) Class 1: 12.5 Hz - 20 kHz (including microphone) Class 2: 16Hz - 16kHz (including microphone) | |||||||||||
Time Weighting | Measurement 1: Slow, Fast, Impulse Measurement 2: Slow, Fast, Impulse | |||||||||||
Display | 2.4” Full Colour TFT 240x320 pixels | |||||||||||
Dual Measurements | Simultaneous dual measurement with independent time and frequency weightings |
Measurement Parameters
dBAir Safety & Environmental | LSPL, LE, LEQ, LMAX, LMIN, Peak, LEP’d, Exposure Points, Dose, Hearing Protector Calculator, Ltm3, Ltm5, Lday, Lnight, Ldn, Lden, NA, 10 user-definable Ln values (preset to: L1, L2, L5, L10, L50, L90, L95, L98, L99) plus LAF* for Noise act assessment. | |||||||||||
Languages | English UK, English US, Chinese, French, German, Italian, Portuguese Brazilian, Russian, Spanish. | |||||||||||
Time History | Short Interval: 10ms to 60m Long Interval: 1s to 24h Smart Timer, Duration Timer or Interval Timer Memory 16GB, 32GB, 64GB Input / Output Connection Micro USB Type B | |||||||||||
Power | Batteries: 4 x AA (1.5V) Life: Up to 12 Hours continuous operation (screen settings dependent) USB Socket | |||||||||||
Size and Dimensions: | Including Pre-Amplifier: 210mm (H) x 70mm (W) x 30mm (D) Excluding Pre-Amplifier: 145mm (H) x 70mm (W) x 30mm (D) | |||||||||||
Weight | 480g approximately (including batteries) |
Technical Specification
Applicable Standards | IEC 61672-1:2013 IEC 61260-1:2014 (Where Octave Bands Fitted) IEC 61252:1993 amendment 1:2000 (Where Exposure Fitted) | |||||||||||
Microphone | Type 1 Pre-Polarised ½” (50mV/Pa) Condenser Microphone -26 dB ± 2 dB re 1V/Pa | |||||||||||
Measurement Ranges | Linear Operating Range: 95dB | |||||||||||
Noise Floor | Typical ’A’ WeightingFrequency WeightingsMeasurement 1: A, C or Z Measurement 2: A, C or Z | |||||||||||
Frequency Range | 1 Hz - 20 kHz (electrical characteristics) Class 1: 12.5 Hz - 20 kHz (including microphone) Class 2: 16Hz - 16kHz (including microphone) | |||||||||||
Time Weighting | Measurement 1: Slow, Fast, Impulse Measurement 2: Slow, Fast, Impulse | |||||||||||
Display | 2.4” Full Colour TFT 240x320 pixels | |||||||||||
Dual Measurements | Simultaneous dual measurement with independent time and frequency weightings |
Measurement Parameters
dBAir Safety & Environmental | LSPL, LE, LEQ, LMAX, LMIN, Peak, LEP’d, Exposure Points, Dose, Hearing Protector Calculator, Ltm3, Ltm5, Lday, Lnight, Ldn, Lden, NA, 10 user-definable Ln values (preset to: L1, L2, L5, L10, L50, L90, L95, L98, L99) plus LAF* for Noise act assessment. | |||||||||||
Languages | English UK, English US, Chinese, French, German, Italian, Portuguese Brazilian, Russian, Spanish. | |||||||||||
Time History | Short Interval: 10ms to 60m Long Interval: 1s to 24h Smart Timer, Duration Timer or Interval Timer Memory 16GB, 32GB, 64GB Input / Output Connection Micro USB Type B | |||||||||||
Power | Batteries: 4 x AA (1.5V) Life: Up to 12 Hours continuous operation (screen settings dependent) USB Socket | |||||||||||
Size and Dimensions: | Including Pre-Amplifier: 210mm (H) x 70mm (W) x 30mm (D) Excluding Pre-Amplifier: 145mm (H) x 70mm (W) x 30mm (D) | |||||||||||
Weight | 480g approximately (including batteries) |