- Industrial Hygiene
- Environmental
- Analytical Laboratory
- Disc Filter Membrane
- Glass Fiber
- Silver Filter Membrane
- Ceramic Filter Membrane
- Aluminum Oxide Filter Membrane
- Mixed Cellulose Ester (MCE) Filter Membrane
- Nylon Filter Membrane
- Polytetrafluorothylene (PTFE) Filter Membrane
- Cellulose Acetate (CA) Filter Membrane
- Hydrophilic Polycarbonate (PCTE) Filter Membrane
- Hydrophobic Polycarbonate (PCTE) Filter Membranes
- PVDF Filter Membrane
- Polypropylene (PP) Filter Membrane
- Polyethersulfone (PES) Filter Membrane
- Polyacrylonitrile (PAN) Filter Membrane
- Hydrophilic, Polyester Track Etch (PETE) Filter Membrane
- Hydrophobic Polyester (PETE) Filter Membrane
- Polyether Ether Ketone (PEEK) Filter Membrane
- Regenerated Cellulose (RC) Filter Membrane
- Quantitative Filter Paper
- Qualitative Filter Paper
- Syringe Filter
- In-line Filter
- Botanical Filter Paper
- Microbiology
- Others
- Disc Filter Membrane
Inter Products Marketing Sdn Bhd
Klang, Selangor, Malaysia.
+6016-305 9138
SONUS GA116I Safety & Environmental System, Class 1
Previous | 10 / 10 | Next |
Castle / NK021
SONUS GA116I Safety & Environmental System, Class 1
SONUS Integrating Sound/Lepd Meter Class 1 (GA116I) c/w Calibrator (Dual level, Class 1) (Includes GA690 Barometer), MK79 Dosemeter Plug-in Microphone and Small Attache Kit Case
Check noise levels in the workplace, environment, pub or club. Ensure that employees and anyone near a noise source is not being subjected to noise levels above dangerous noise levels. Take regular measurements and monitor certain areas to ensure that noise control measures remain effective.
Technical Specification
Applicable Standards | IEC 61672-1:2013 (Integrating, Sound Exposure and Sound Level Meters) |
IEC 60651:2001 (Sound Level Meters) | |
IEC 60804:2000 (Integrating Function) | |
Microphone and Preamplifier | Type 7146A Pre-Polarised ½” (13.2 mm) Free-Field, Electret Condenser Microphone: 20Hz – 20KHz ± 2dB –32 dB ± 3 dB re 1V/Pa Custom pre-amplifier design Typical actuator to free-field correction factor (based on 500Hz=0) is shown below |
Display | Back-lit LCD panel (8x1 Characters) Alpha-Numeric display for measured results |
Level Range | Total Measuring Range: 41-140 |
Linear operating range (IEC61672-1): 65dB 3 | |
3 Display Ranges (IEC61672-1): 35-100 55-120 - Reference Range 75-140 | |
Noise Floor | Typical ’A’ Weighting ‘C’ Weighting |
Frequency Weighting | ‘A’ and ’C’ to IEC 61672-1:2002 and IEC 60651:2001 |
Frequency Range | 12.5 Hz - 20 kHz (including microphone) |
1 Hz - 20 kHz (electrical characteristics) | |
Time Weighting | Slow and Fast |
Instrument Response | Simultaneous rms. and Peak |
Measurement Response | Lp (Sound Pressure Level), Leq (Equivalent Sound Level), Lmax (maximum Level), Cpeak (Max. Peak Level), LEpd (Sound Exposure Level), LAE (Single Event Sound Exposure Level) Other Displays: Elapsed time, Overload, Battery Life |
Calibration | Software controlled 91.0 to 120.0 dB (1kHz) in 0.1 dB steps |
Processing | A to D Converter: 12-bit Controller: 8MHz, micro-controller |
Output | AC Output = 16.4mVrms at 94dB (un-weighted and not affected by range) DC Output = 40mV/dB (weighted and ranged) |
Power Requirement | Batteries: 1 x 6LR61 (size PP3), Life: >12 hours (alkaline batteries, continuous operation) |
Size | Dimensions: 60mm (width) x 30mm (depth excluding pocket clip) x 135mm (height without microphone) or 210mm (height with microphone) |
Weight | 200gms (without battery) |
Manuals | Multi-language manuals*: French, German, Spanish and Italian |
Accessories GA607 Dual Level Calibrator: KA010 Kit Case for GA116I, GA607 and Accessories |