Visit
Official Website

Inter Products Marketing Sdn Bhd
Klang, Selangor, Malaysia.
+6016-305 9138

Sonus GA116L Safety & Environmental Data-logging Sound System

Previous 8 / 10 Next


Castle / NK001

Sonus GA116L Safety & Environmental Data-logging Sound System

Class 1 GA116L - Safety/Environmental Data-logging Sound Meter c/w GA607 Calibrator, Dual Level, Class 1 (includes GA690 Barometer), KA010 Small Attache Kit Case and PC007 dBdataPRO Noise Analysis Software and Cable

 
The Sonus L model features parameters for measuring a wide range of applications. The Safety and Environmental Data Logging Sound System is designed for Noise at Work and Environmental measurements and features the Sonus Logging meter. Select Noise at Work measurements for logging noise levels in the workplace, or switch the removable microphone for the dosemeter cable microphone (available separately) and measure personal noise and dose levels. Environmental parameters include L10 and L90 measurements and a third selectable percentile level. The kit is available in 2 options, with GA116L Class 1 meter or GA216L Class 2 meter.
 

Technical Specification

IEC61672-1-2013 (Sound Level Meters) IEC61252-1993 (Personal Sound Exposure Meters) BS4142:2014 Methods for rating and assessing industrial and commercial sound
 

Selectable level ranges on the GA116L:

RANGE DISPLAY RANGE LINEAR RANGE PEAK RANGE
30-100 29 – 101dB 30 – 100dB 40 – 103dB
50-120 59 – 121dB 50 – 120dB 60 – 123dB
70-140 69 – 141dB 70 – 140dB 80 – 143dB


Linear Operating Range 70dB
Detector Characteristics RMS and Peak
Frequency Weighting ‘A’, ‘C’ & ‘Z’ Weighted in Accordance with IEC 61672-1-2002 Combinations of ‘A’, ‘A’&’C’ simultaneous or ‘A’&’Z’ simultaneous available for Leq, Lmax and Pmax
Time Weighting ‘Slow’, ’Fast’ and ‘Impulse’ in Accordance with IEC 61672-1-2002
Exchange Rate 3dB, 4dB or 5dB
Criterion Level 75dB, 80dB, 85dB or 90dB
Threshold Level -5dB, -10dB or OFF
Peak 3dB above top of selected range
Display Custom alphanumeric LCD, digit size 7mm x 5mm
Memory 2100 Data Intervals Maximum
Microphone/ Preamplifier ACO 7146A pre-polarised ½” condenser microphone, 25mV / Pa
Calibration 91.0 to 120.0dB @ 1KHz
Batteries 1 x PP3 (9V) Approximately 12 hours continuous use
Operating Temperature Operating Range: -10 to + 50ºC
Humidity Effect: < 0.5dB from 25% to 90% RH
Vibration No effect on instrument

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Messages*