- Industrial Hygiene
- Environmental
- Analytical Laboratory
- Disc Filter Membrane
- Glass Fiber
- Silver Filter Membrane
- Ceramic Filter Membrane
- Aluminum Oxide Filter Membrane
- Mixed Cellulose Ester (MCE) Filter Membrane
- Nylon Filter Membrane
- Polytetrafluorothylene (PTFE) Filter Membrane
- Cellulose Acetate (CA) Filter Membrane
- Hydrophilic Polycarbonate (PCTE) Filter Membrane
- Hydrophobic Polycarbonate (PCTE) Filter Membranes
- PVDF Filter Membrane
- Polypropylene (PP) Filter Membrane
- Polyethersulfone (PES) Filter Membrane
- Polyacrylonitrile (PAN) Filter Membrane
- Hydrophilic, Polyester Track Etch (PETE) Filter Membrane
- Hydrophobic Polyester (PETE) Filter Membrane
- Polyether Ether Ketone (PEEK) Filter Membrane
- Regenerated Cellulose (RC) Filter Membrane
- Quantitative Filter Paper
- Qualitative Filter Paper
- Syringe Filter
- In-line Filter
- Botanical Filter Paper
- Microbiology
- Others
- Disc Filter Membrane
Inter Products Marketing Sdn Bhd
Klang, Selangor, Malaysia.
+6016-305 9138
10mm Dorr-Oliver Nylon Cyclone Assembly
Previous | 1 / 2 | Next |
Gilian / 800061
10mm Dorr-Oliver Nylon Cyclone Assembly
This Dorr-Oliver unit meets NIOSH sampling requirements for 10mm nylon cyclones, as specified for nuisance dust (#0600) and silica dust (#7500, 7501, 7601 and 7602).
It is designed to separate the respirable fraction of airborne dust from the nonrespirable fraction; i.e. airborne particles with aerodynamic diameters between 0.2 and 10 microns, capable of producing pneumonconiosus lung disease with long-term exposure. Designed for pneumonconiosus-producing dusts, it can also be effectively used to monitor the respirable fraction of all types of dusts, from high toxic to nuisance particulate.
The unit consists of a two-stage cyclone and a lightweight aluminum frame, which mounts a standard 3-part 37mm filter cassette, with membrane filter. When air enters the cyclone stage at 1.7 LPM (as recommended by NIOSH), the larger nonrespirable particles are centrifugally separated out and drop into a removable lower grit pot. The smaller, respirable particles pass on to the cassette, where they are captured by the filter membrane.
Cyclone GraphNote how closely the separation achieved by the Cyclone Sampler (red curve) follows the convention for separation of respirable particles, as specified by ACGIH (black curve). Few other cyclone separators show such a close fit of actual to ideal performance. For example, 100% of 10 micron particles and 50% of 4 micron particles are removed by the cyclone. This corresponds with 0% of 10 micron particles and 50% of 4 micron particles that penetrate the lower lung.
Technical Specifications
CUT POINT | 4 micron |
FLOW RATE | 1.7 LPM |
MATERIAL | Nylon |
TYPE | Dorr-Oliver |