- Industrial Hygiene
- Environmental
- Analytical Laboratory
- Disc Filter Membrane
- Glass Fiber
- Silver Filter Membrane
- Ceramic Filter Membrane
- Aluminum Oxide Filter Membrane
- Mixed Cellulose Ester (MCE) Filter Membrane
- Nylon Filter Membrane
- Polytetrafluorothylene (PTFE) Filter Membrane
- Cellulose Acetate (CA) Filter Membrane
- Hydrophilic Polycarbonate (PCTE) Filter Membrane
- Hydrophobic Polycarbonate (PCTE) Filter Membranes
- PVDF Filter Membrane
- Polypropylene (PP) Filter Membrane
- Polyethersulfone (PES) Filter Membrane
- Polyacrylonitrile (PAN) Filter Membrane
- Hydrophilic, Polyester Track Etch (PETE) Filter Membrane
- Hydrophobic Polyester (PETE) Filter Membrane
- Polyether Ether Ketone (PEEK) Filter Membrane
- Regenerated Cellulose (RC) Filter Membrane
- Quantitative Filter Paper
- Qualitative Filter Paper
- Syringe Filter
- In-line Filter
- Botanical Filter Paper
- Microbiology
- Others
- Disc Filter Membrane
Inter Products Marketing Sdn Bhd
Klang, Selangor, Malaysia.
+6016-305 9138
Primary Flow Calibrator, 2.5 - 300 LPM
Previous | 2 / 7 | Next |
TSI / 4046
Primary Flow Calibrator, 2.5 - 300 LPM
4046 Primary calibrator kit c/w soft-sided carrying case, battery pack, tubing, user guide and NIST-traceable calibration certificate
The TSI 4046 Flow Calibrator is portable, battery-operated unit that is lightweight, easy to use and accurate within 2% of reading. Volumetric flow rate is displayed continuously so adjustments to pump flow can be made in real-time.
Personal sampling pumps must be calibrated before and after each use and routinely checked during use. Flow calibrators are used to adjust and measure the flow rate. of air sampling instruments.
Why is the adjustment and calibration of air sampling instruments necessary? Instruments that sample air must be flow adjusted, calibrated and routinely checked to ensure the accuracy of flow rate. The frequency of flow adjustment and/or calibration depends on the use, care and handling of the air sampling instruments and the regulations they are complying with. Determining exposure to various physical, chemical, radiological and biological substances is based on the accuracy of the total volume of air sampled and the sample duration.
Features:
Provides continuous real-time volumetric flow rate readings, so pump adjustment and calibration is fast and easy
Battery powered, compact and lightweight
Field portable—use the same calibrator for adjustment, calibration and periodic flow checks
Kits come complete and are ready to use
Technical Specifications
Flow Ranges | 2.5 - 300 LPM |
Accuracy | 2% |
Max Flow Rate | 300 LPM |
Type | Dry Gas |