Visit
Official Website

Inter Products Marketing Sdn Bhd
Klang, Selangor, Malaysia.
+6016-305 9138

Allin Plus-5 Personal Air Sampler Single Pack Kit

Previous 7 / 8 Next


AP Buck / APB-905320

Allin Plus-5 Personal Air Sampler Single Pack Kit (Flow Rate: 5 to 5000 cc/min.)

Allin Plus-5 Single Pack kit, 230V c/w Allin Plus-5 pump with single pack NiMH battery,  standard 120V or 240V AC battery charger, Luer hose adapter, shirt/hose clip, 3 feet of vinyl hose and operating manual. Universal low flow holder for sorbent tubes & PC link software and cable sold seperately.

 
The BUCK Allin Plus 5 series is a personal air sampler suitable for use in location where flammable gases, vapors, dust, fibers or fly-ings are present. It has steel fiber filled housing for RFI/EMI shielding, exclusive electronic circuit board for constant flow control, an LCD display with 2 lines of 16 characters, a single diaphragm pump mech-anism, and a rechargeable NiMH battery pack.
 
The purpose of this pump is to draw air contaminants in through a sampling media such as 25 and 37mm filter cassettes, bubble im-pingers, long-duration color detector tubes; to gauge personnel expo-sure to gases, vapors, particulates, aerosols, etc.
 
No tools are required to operate this pump and a password pro-tected keypad locking system provides uninterrupted operation. The main display allows quick selection to RUN (for sampling) or MENU (to reset pumps data). Other features include elapsed time, flow rate, and accumulated volume.
 
Allin Plus models include data logging, programmable feature which allows the pump for unattended Start/Stop operation. Tem-perature and Barometric Pressure compensation in STP mode. The PC link capability lets you download the sampling data into a PC with Windows XP/ Windows 7 operating system using the RS232 COM port and the Buck PC link cable
 

Features:

  • UL 913 and CAN/CSA-C22.2 Intrinsically safe certified: Suitable for use in Class I, II, III, Div 1 Groups A-G, T3 Hazardous locations.
  • Allin Plus models capable of Data logging and can be programmed for multiple Start/ Stop and Duration Sampling.**
  • Temperature and Barometric Pressure Compensated flow available in the Allin Plus models only.**
  • Runs 14 hours @ 2.0 LPM (37 mm 0.8μ filter)
  • High back pressure compensation, up to 50” of w.c.@2LPM
  • Accuracy: ± 5% of compensation range
  • Flow compensation for filter plugging and battery voltage
  • Dual flow range easily handles Impingers, cyclones, and tubes
  • “Auto-restart” within one minute of a flow fault
  • Includes single pack battery and run time could be extended with the use of optional triple pack.
  • Battery pack rechargeable while attached or separately
  • Compact, rugged, and quiet
  • Stainless steel belt clip with built-in tripod connector
  • Key pad lock system
  • One year warranty
 

Technical Specifications:

Flow Range: 0.8-5LPM (800-5000 cc/min)
5—799 cc/min With Universal Low Flow Holder
 
Compensation Range:
5000 cc/min up to 10” water back pressure
4000 cc/min up to 20” water back pressure
3000 cc/min up to 30” water back pressure
2000 cc/min up to 50” water back pressure
1000 cc/min up to 30” water back pressure
800 cc/min up to 15” water back pressure
Accuracy: ± 5% of Compensation Range
 
Run Time (hrs) at different backpressure and flow rate

(cc/min) Backpressure (inches of water)
Flow Rate  5”  10”  15”  20”  30”  40”  50”
1000 18hr  14 hr 12 hr 10 hr 7 hr    
2000 14hr  12 hr 10 hr 8 hr 6 hr 4 hr 3 hr
3000 11 hr 9 hr 8 hr 7 hr 4 hr    
4000 9 hr 7 hr 5 hr 3 hr      
5000 6 hr            

Low Flow using Universal Low Flow Holder 5 to 799cc/min: 1- 8 hours depending



Data Storage Flow rate, elapsed clock time, accumulated
Allin Plus Only volume, temperature, DP and any Flow Faults are logged in the memory for download to PC.
Display Backlit LCD with 2 lines of 16 Characters
Normal Operation Battery Level, Flow Rate, Elapsed Time, Volume Collected, Timer, DP .
Flow Fault Displays Flow Fault, or Filter Off
Power Supply Single Pack, NiMH Batteries: 4.8V, 2.15 Ah
Triple Pack, NiMH Batteries: 4.8V, 6.45 Ah
Charger Type Standard Wall Charger
Standard Charger Input Voltage 120 VAC - 240 VAC
**Approvals UL913 and CAN/CSA-C22.2 Intrinsically safe certified. Suitable for use in Class I, II, III Div 1 Groups A-G,T3 Hazardous locations.
ATEX Pending
Temperature Operating 32°F to 113°F (0°C to 45°C)
Storage 32°F to 113°F (0°C to 45°C)
Charging 50°F to 104°F (10°C to 40°C)
Case Polycarbonate steel fiber filled, RFI/EMI-shielded
Size 4.5”H x 4”W x 2”D(11.4 cm H x 10.2 cm W x 5 cm D)
Weight 19oz(539g)

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Messages*