- Industrial Hygiene
- Environmental
- Analytical Laboratory
- Disc Filter Membrane
- Glass Fiber
- Silver Filter Membrane
- Ceramic Filter Membrane
- Aluminum Oxide Filter Membrane
- Mixed Cellulose Ester (MCE) Filter Membrane
- Nylon Filter Membrane
- Polytetrafluorothylene (PTFE) Filter Membrane
- Cellulose Acetate (CA) Filter Membrane
- Hydrophilic Polycarbonate (PCTE) Filter Membrane
- Hydrophobic Polycarbonate (PCTE) Filter Membranes
- PVDF Filter Membrane
- Polypropylene (PP) Filter Membrane
- Polyethersulfone (PES) Filter Membrane
- Polyacrylonitrile (PAN) Filter Membrane
- Hydrophilic, Polyester Track Etch (PETE) Filter Membrane
- Hydrophobic Polyester (PETE) Filter Membrane
- Polyether Ether Ketone (PEEK) Filter Membrane
- Regenerated Cellulose (RC) Filter Membrane
- Quantitative Filter Paper
- Qualitative Filter Paper
- Syringe Filter
- In-line Filter
- Botanical Filter Paper
- Microbiology
- Others
- Disc Filter Membrane
Inter Products Marketing Sdn Bhd
Klang, Selangor, Malaysia.
+6016-305 9138
Allin-5 5 pk Pump kit with Five Standard charger and case
Previous | 6 / 8 | Next |
AP Buck / APB-905250
Allin-5 5 pk Pump kit with Five Standard charger and case (Flow Rate: 5 to 5000 cc/min.)
''Allin-5 5 pk Pump kit c/w Allin-5 with single pack NiMH batteries (5 units), Luer hose adapter, shirt/hose clip, and 3 feet of vinyl hose, operating manuals, Five standard chargers 100-240VAC and a durable hard plastic case that accommodates additional accessories. Universal low flow holder for sorbent tubes sold seperately''.
The BUCK Allin 5 series is a personal air sampler suitable for use in location where flammable gases, vapors, dust, fibers or fly-ings are present. It has steel fiber filled housing for RFI/EMI shielding, exclusive electronic circuit board for constant flow control, an LCD display with 2 lines of 16 characters, a single diaphragm pump mech-anism, and a rechargeable NiMH battery pack.
The purpose of this pump is to draw air contaminants in through a sampling media such as 25 and 37mm filter cassettes, bubble im-pingers, long-duration color detector tubes; to gauge personnel expo-sure to gases, vapors, particulates, aerosols, etc.
No tools are required to operate this pump and a password pro-tected keypad locking system provides uninterrupted operation. The main display allows quick selection to RUN (for sampling) or MENU (to reset pumps data). Other features include elapsed time, flow rate, and accumulated volume.
Features:
- UL 913 and CAN/CSA-C22.2 Intrinsically safe certified: Suitable for use in Class I, II, III, Div 1 Groups A-G, T3 Hazardous locations.
- Temperature and Barometric Pressure Compensated flow available in the Allin Plus models only.**
- Runs 14 hours @ 2.0 LPM (37 mm 0.8μ filter)
- High back pressure compensation, up to 50” of w.c.@2LPM
- Accuracy: ± 5% of compensation range
- Flow compensation for filter plugging and battery voltage
- Dual flow range easily handles Impingers, cyclones, and tubes
- “Auto-restart” within one minute of a flow fault
- Includes single pack battery and run time could be extended with the use of optional triple pack.
- Battery pack rechargeable while attached or separately
- Compact, rugged, and quiet
- Stainless steel belt clip with built-in tripod connector
- Key pad lock system
- One year warranty
Technical Specifications:
Flow Range: 0.8-5LPM (800-5000 cc/min)
5—799 cc/min With Universal Low Flow Holder
Compensation Range:
5000 cc/min up to 10” water back pressure
4000 cc/min up to 20” water back pressure
3000 cc/min up to 30” water back pressure
2000 cc/min up to 50” water back pressure
1000 cc/min up to 30” water back pressure
800 cc/min up to 15” water back pressure
Accuracy: ± 5% of Compensation Range
Run Time (hrs) at different backpressure and flow rate
(cc/min) Backpressure (inches of water) | |||||||
Flow Rate | 5” | 10” | 15” | 20” | 30” | 40” | 50” |
1000 | 18hr | 14 hr | 12 hr | 10 hr | 7 hr | ||
2000 | 14hr | 12 hr | 10 hr | 8 hr | 6 hr | 4 hr | 3 hr |
3000 | 11 hr | 9 hr | 8 hr | 7 hr | 4 hr | ||
4000 | 9 hr | 7 hr | 5 hr | 3 hr | |||
5000 | 6 hr |
Low Flow using Universal Low Flow Holder 5 to 799cc/min: 1- 8 hours depending on backpressure.
Data Storage | Flow rate, elapsed clock time, accumulated |
Display | Backlit LCD with 2 lines of 16 Characters |
Normal Operation | Battery Level, Flow Rate, Elapsed Time, Volume Collected, Timer, DP . |
Flow Fault Displays | Flow Fault, or Filter Off |
Power Supply |
Single Pack, NiMH Batteries: 4.8V, 2.15 Ah Triple Pack, NiMH Batteries: 4.8V, 6.45 Ah |
Charger Type | Standard Wall Charger |
Standard Charger Input Voltage | 120 VAC - 240 VAC |
**Approvals | UL913 and CAN/CSA-C22.2 Intrinsically safe certified. Suitable for use in Class I, II, III Div 1 Groups A-G,T3 Hazardous locations. |
ATEX | Pending |
Temperature |
Operating 32°F to 113°F (0°C to 45°C) Storage 32°F to 113°F (0°C to 45°C) Charging 50°F to 104°F (10°C to 40°C) |
Case | Polycarbonate steel fiber filled, RFI/EMI-shielded |
Size | 4.5”H x 4”W x 2”D(11.4 cm H x 10.2 cm W x 5 cm D) |
Weight | 19oz(539g) |